😎 TODOS NUESTROS PRECIOS INCLUYEN IVA
📦 ENVÍOS EL MISMO DÍA, ANTES DE LA 1PM DE L-V
Tu envío es gratis en compras mayores a $2,999 MXN
Estimado para ser entregado entre 3-5 días hábiles después del pago en productos disponibles.
You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).
You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).
If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.
El medidor de conductividad de mesa serie LAQUA 1000 es una solución perfecta para realizar mediciones de electroquímica en el laboratorio. Cuenta con cinco modelos y diferentes configuraciones; de canal sencillo o doble canal y con versión disponible para medir hasta 7 valores. Los parámetros disponibles son: pH, ORP, conductividad, salinidad, resistividad, TDS, ION y temperatura.
Es un medidor intuitivo y fácil de usar con pantalla de 14 cm, opera a partir de un panel suave al tacto, el cual es resistente a golpes y químicos. Maniobrabilidad con el brazo del electrodo que es ligero, puede girar 360° y se puede integrar al medidor o ser instalado de forma independiente. Es sofisticado, sencillo, resistente y confiable. Funciones sobresalientes como: configuración intuitiva, valoración del estado del electrodo, calibración a 5 puntos, función de estabilización, mensajes de diagnóstico, gestión de datos con memoria interna, GLP/ GMP y salida RS232 o USB.
Si este producto se encuentra AGOTADO el tiempo de entrega es de 35 días naturales aproximadamente.
Modelo | EC-1100 |
Parámetros | EC / TDS / Res / Sal / Temp |
Canales | 1 canal |
Rango de conductividad (EC) | 0 μS/cm a 19.99 μS/cm |
0 μS/cm a 1,999.0 μS/cm | |
0 μS/cm a 20.00 mS/cm | |
0 μS/cm a 200.0 mS/cm | |
0 μS/cm a 2,000.0 mS/cm | |
Resolución EC | 0.05 % del rango completo |
Precisión EC | ± 0.6 % del rango completo, ± 1.5 % del rango completo> 18.0 mS/cm |
Temperatura de referencia | 15 a 30 °C (ajustable) |
Coeficiente de temperatura | 0.0 a 10.0 % (ajustable) |
Constante de celda | 0.1 / 1.0 / 10.0 |
Unidad de medida | μS/cm, mS/cm, S/m (auto / manual) |
Puntos de calibración | 4 puntos (auto / manual) |
Rango TDS | 0.01 a 9.99 ppm, 0.1 a 999.9 ppm, 1 ppm a 10.00 ppt, 10 ppm a 100.0 ppt, 100.0 ppm a 1,000.0 ppt |
Resolución TDS | 0.01 ppm, 0.1 ppt |
Precisión TDS | ± 0.1 % de escala completa |
Curva de calibración | EN27888 / 442 / lineal / NaCl |
Rango de resistividad | 0.000 Ω/cm a 20,000 Ω/cm, 0.00 Ω/cm a 200.0 MΩ/cm |
Resolución Res | 0.1 % de escala completa |
Precisión Res | 0.06 % de escala completa (± 1.5 % de la escala completa> 1.80 MΩ/cm) |
Rango de salinidad | 0.0 a 100.0 ppt, 0.00 a 10.00 % |
Resolución Sal | 0.1 ppt, 0.01 % |
Precisión Sal | ± 0.2 % escala completa |
Curva de calibración | NaCl / agua de mar |
Rango de temperatura | -30.0 a 130.0 °C |
Resolución | 0.1 °C |
Exactitud | ± 0.4 °C |
Datos de memoria | 500 datos |
Función de estabilización | sí |
Mensaje de diagnóstico | sí |
Pantalla | LCD |
Conexiones | BNC, phono jack y DC |
Interface | USB, RS232C |
Soporte de electrodo | Integrado |
Dimensiones | 170x174x73 mm |
Peso | 500 g |
Voltaje | 100 a 240 V, AC, 50/60 Hz |
Modelo / Catálogo | Configuración |
EC1100-S | Medidor EC1100, soporte de electrodo, electrodo de conductividad 9382-10D, soluciones de 84 μS/cm, 1,413 μS/cm, 12.88 mS/cm, 111.8 mS/cm (250 mL), adaptador y protector plástico |
HB-3999960179 | |
EC1100 | Medidor EC1100, soporte de electrodo, adaptador y protector plástico |
HB-3200647411 |
You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).
You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).
If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.
We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
¡Gracias por suscribirte!
¡Este correo ha sido registrado!